Bucket elevator Data

Dimensions

Calculating power consumption

For a directly coupled gear motor, power consumption in kW is:

(K × Y × (H + 6)) / 347

where

K = capacity in tonnes per hour

Y = 1.15 for grain and 1.25 for flour

H = height in metres

The maximum amount per bucket is reduced to 75% of the maximum number of buckets as for the conveyance of flour.

Please note that counterflow feeding will reduce the capacity by about 15%.

Specifications D 133D 200 ID 200 IID 260D 390D480
Max. capacity*t/h5/10/1520/25/3040/50/6080/100/120150/200250/300/360
Max. capacity*m3/h7/14/2027/33/4053/67/82107/134/160200/267334/400/480
Buckets/mpcs.4.5/9/12.58.5/10.5/12.56.5/8/105.5/7/84.5/74.5/5/6
Bucket type SPS80-80100-90140-120200-150300-165A370-215
Belt type** EP500/4
EP500/4
EP630/4
EP630/4
EP630/4
EP630/4
Belt widthmm100120160215330440
Belt pulleymmØ 300Ø 325Ø 325Ø 415Ø 515Ø 615
Min/max speedm/s1.8/2.51.8/3.11.8/3.11.8/3.11.8/3.11.8/3.1
Max speed, flourm/s2.02.32.32.32.32.3
MotorkW1.1 - 3.02.2 - 5.52.2 - 7.55.5 - 15.07.5 - 30.015.0 - 45.0

* Capacities are based on a specific gravity of 0.75 t/m3 and 85% Z2 filling of buckets.